Detail NR1 ELEC/INST RM/KL/CM
2023-08-16
L63-RM1-PMR-SERVICE-ANALYSER
Wahyu Adi Triono
Problem: sample line at L63 2K1 and L63 2K3 plug from material coal, inject by water to tube sample line and clean use instrument air
Action:
clean filter, flange, sample line, membran pump, filter balston and humidity sensor, probe

Status: done